1.
J Synchrotron Radiat ; 21(Pt 2): 315-24, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562552

RESUMO

The performance of a cryogenically cooled double-crystal silicon monochromator was studied under high-heat-load conditions with total absorbed powers and power densities ranging from 8 to 780 W and from 8 to 240 W mm(-2), respectively. When the temperature of the first crystal is maintained close to the temperature of zero thermal expansion of silicon, the monochromator shows nearly ideal performance with a thermal slope error of 0.6 µrad. By tuning the size of the first slit, the regime of the ideal performance can be maintained over a wide range of heat loads, i.e. from power densities of 110 W mm(-2) (at total absorbed power of 510 W) to 240 W mm(-2) (at total absorbed power of 240 W).

2.
J Synchrotron Radiat ; 17(1): 107-18, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20029119

RESUMO

The first phase of the ESRF beamline ID23 to be constructed was ID23-1, a tunable MAD-capable beamline which opened to users in early 2004. The second phase of the beamline to be constructed is ID23-2, a monochromatic microfocus beamline dedicated to macromolecular crystallography experiments. Beamline ID23-2 makes use of well characterized optical elements: a single-bounce silicon (111) monochromator and two mirrors in Kirkpatrick-Baez geometry to focus the X-ray beam. A major design goal of the ID23-2 beamline is to provide a reliable, easy-to-use and routine microfocus beam. ID23-2 started operation in November 2005, as the first beamline dedicated to microfocus macromolecular crystallography. The beamline has taken the standard automated ESRF macromolecular crystallography environment (both hardware and software), allowing users of ID23-2 to be rapidly familiar with the microfocus environment. This paper describes the beamline design, the special considerations taken into account given the microfocus beam, and summarizes the results of the first years of the beamline operation.


Assuntos
Biopolímeros/química , Cristalografia por Raios X/instrumentação , Lentes , Síncrotrons/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , França , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Synchrotron Radiat ; 16(Pt 6): 803-12, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19844017

RESUMO

ID14-4 at the ESRF is the first tunable undulator-based macromolecular crystallography beamline that can celebrate a decade of user service. During this time ID14-4 has not only been instrumental in the determination of the structures of biologically important molecules but has also contributed significantly to the development of various instruments, novel data collection schemes and pioneering radiation damage studies on biological samples. Here, the evolution of ID14-4 over the last decade is presented, and some of the major improvements that were carried out in order to maintain its status as one of the most productive macromolecular crystallography beamlines are highlighted. The experimental hutch has been upgraded to accommodate a high-precision diffractometer, a sample changer and a large CCD detector. More recently, the optical hutch has been refurbished in order to improve the X-ray beam quality on ID14-4 and to incorporate the most modern and robust optical elements used at other ESRF beamlines. These new optical elements will be described and their effect on beam stability discussed. These studies may be useful in the design, construction and maintenance of future X-ray beamlines for macromolecular crystallography and indeed other applications, such as those planned for the ESRF upgrade.


Assuntos
Cristalografia por Raios X/instrumentação , Síncrotrons/instrumentação , Substâncias Macromoleculares/química , Difração de Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS